Industrial Switches and Media Converters with PoE |
Brief |

Managed PoE Switches ( L2+/L2-managed, Web-managed )

 |
NIS-3500-3426PGE 16 PoE Gigabit Ethernet 30W
IEEE 802.3/802.3u/802.3ab/802.3x, 8K MAC, 4Mb buffer
IEEE 802.3at/802.3af (PD Alive Check), 16 ports 20-30W
IGMP snooping; STP, RSTP, MSTP, ERPS, BPDU Guard; LACP
QoS, CoS, DSCP, VLAN (MAC/Protocol-based, PVE, 802.1Q tag, QinQ)
Telnet, CLI, Web, SNMP, RADIUS, TACACS+, ACL, DHCP option 82
Enhanced G.8032 ERPSv2 Ring protection < 50ms for single ring
2 Digital Input (DI), 2 Digital Output (DO)
Redundant Power Input 48-56VDC; Total PoE Budget 320W
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 152x107x84mm
|
NIS-3500-3426PGE new | 63PG1622 | 16 10/100/1000T PoE 30W + 2 SFP/1G + 2 TP/1G; ERPS, DI/DO |
 |
NIS-3500-2408PGX 8 PoE Gigabit Ethernet 30W
IEEE 802.3/802.3u/802.3ab/802.3x, 16K MAC, 12Mb buffer
IEEE 802.3at/802.3af (PD Alive Check), 8 ports 30W
IGMP snooping, STP, RSTP, G.8032 ERPS, DHCP option 82, LACP
QoS, CoS, DSCP, VLAN (Port-based, 802.1Q tag, QinQ), Syslog
Telnet, CLI, Web, SNMP, RMON, RADIUS, TACACS+, SSL, SSH
Support X-Ring with auto-recovery time 20 ms
Redundant Power Input 48-57VDC; Total PoE Budget 240W
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 145x118x72mm
|
NIS-3500-2408PGX | 63PX0804 | 8 10/100/1000T PoE 30W + 4 1G/10G SFP; ERPS, Modbus |
 |
NIS-3500-3412PGE 8 PoE Gigabit Ethernet 36W
IEEE 802.3at/3af (PD Alive Check), 8 ports PoE 36W
IGMP snooping; STP, RSTP, MSTP, G.8032 ERPSv2, BPDU Guard; LACP
QoS, CoS, DSCP, VLAN (MAC/Protocol-based, PVE, 802.1Q tag, QinQ)
Telnet, CLI, Web, SNMP, RADIUS, TACACS+, ACL, DHCP option 82
2 Digital Input (DI), 2 Digital Output (DO)
Redundant Power Input 48-56VDC; Total PoE power budget: 240W
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 152x107x77mm
|
NIS-3500-3412PGE new | 63PG0804 | 8 10/100/1000T PoE 36W + 4 SFP/1G, 2 DI/DO |
 |
WI-PMS312GF-I 8 PoE Gigabit Ethernet 30W
IEEE 802.3/802.3u/802.3ab/802.3x, 8K MAC, 10K Jumbo Frame
IEEE 802.3af/at/bt(PD Alive Check) /Passive
IGMP snooping; ERPS, EAPS, STP, RSTP, MSTP;
QoS, VLAN (Port-based, 802.1q tag-based), Syslog, Radius
Console/CLI, Web GUI, Telnet, SNMP, Syslog, RMON
Redundant Power Input 48-56VDC; Total PoE power budget 300W
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 188x130x50mm
|
WI-PMS312GF-I new | 63P8MG30 | 8 10/100/1000T PoE 802.3af/at/bt/Passive + 4 SFP/1G |
 |
NIS-3500-3204PGE 4 PoE Gigabit Ethernet 802.3bt
IEEE 802.3af/802.3at/802.3bt (PD Alive Check), 4 ports PoE up to 95W
802.3bt PoE 90W | UPoE(PoH) 95W | 802.3at Standard 36W | Force 60W
IGMP snooping; STP, RSTP, MSTP, G.8032 ERPSv2, BPDU Guard; LACP
QoS, CoS, DSCP, VLAN (MAC/Protocol-based, PVE, 802.1Q tag, QinQ)
Telnet, CLI, Web, SNMP, RADIUS, TACACS+, ACL, DHCP option 82
Enhanced G.8032 ERPSv2 Ring protection < 50ms for single ring
2 Digital Input (DI), 2 Digital Output (DO)
Redundant Power Input 48-56VDC; Total PoE power budget 240W
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 152x72x107mm
|
NIS-3500-3204PGE new | 63P4G403 | 4 10/100/1000T 802.3bt PoE + 2 SFP/1G + 1 TP/1G; ERPS, DI/DO |
 |
NIS-3500-2204PGE 4 PoE Gigabit Ethernet 30W
IEEE 802.3/802.3u/802.3ab/802.3x
IEEE 802.3at/802.3af (PD Alive Check), 4 ports PoE 36W
IGMP snooping; STP, RSTP, MSTP, G.8032 ERPSv2, BPDU Guard; LACP
QoS, CoS, DSCP, VLAN (MAC/Protocol-based, PVE, 802.1Q tag, QinQ)
Telnet, CLI, Web, SNMP, RADIUS, TACACS+, ACL, DHCP option 82
Enhanced G.8032 ERPSv2 Ring protection < 50ms for single ring
Redundant Power Input 48-56VDC; Total PoE power budget 144W
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 135x88x50mm
|
NIS-3500-2204PGE new | 63P4G402 | 4 10/100/1000T PoE 36W + 2 SFP/1G, G.8032 ERPSv2 |

 |
NIS-3200-218PSG
| 8 ports PoE 30W
IEEE 802.3/802.3u/802.3ab/802.3x/802.3at/af (PoE auto detection)
16K MAC, 2Mbit buffer, Switch fabric 20Gbps
Redundant Power Input 48-56VDC
PoE pin assignment: 1/2(+), 3/6(-). Mode A EndSpan PoE
PSE 30W/port; Total PoE power budget: 240W
Housing: IP40 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 143x104x48mm
|
NIS-3200-218PSG | 63P8SG28 | Industrial switch: 8 10/100/1000T PoE 30W + 2 SFP/1G |
 |
NIS-3200-204PSG
| 4 ports PoE 30W
IEEE 802.3/802.3u/802.3ab/802.3x/802.3at/af (PoE auto detection)
8K MAC, 1Mbit buffer, Switch fabric 12Gbps
Redundant Power Input 48-56VDC
PoE pin assignment: 1/2(+), 3/6(-). Mode A EndSpan PoE
PSE 30W/port; Total PoE power budget: 120W
Housing: IP40 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 143x104x48mm
|
NIS-3200-204PSG | 63P4SG24 | Industrial switch: 4 10/100/1000T PoE 30W + 2 SFP/1G |
 |
NIS-3200-122PSG
| 2 ports PoE 802.3bt
IEEE 802.3/802.3u/802.3ab/802.3x/802.3af/802.3at/802.3bt
1K MAC, 0,5Mbit buffer, Switch fabric 8 Gbps
PoE pin assignment: Mode A | Mode B | 4-pairs 1/2, 4/5(+); 3/6, 7/8(-)
Redundant power input 48-57VDC; Total PoE power budget: 180W
Relay alarm: Power off, PoE off, network broken
DIP switches: SFP mode selection | PoE auto-check function
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 101x65x36mm
|
NIS-3200-122PSG | 69P2SG92 | Industrial switch: 2 10/100/1000T PoE 802.3bt + 2 SFP/1G, reboot PD |
 |
NIS-3200-104PSG
| 4 ports PoE 30W | Voltage Booster 24 VDC
IEEE 802.3/802.3u/802.3ab/802.3x/802.3at/af (PoE auto detection)
8K MAC, 1Mbit buffer, Switch fabric 10Gbps
PoE pin assignment: 4/5(+), 7/8(-)
Redundant power input 24-56VDC; Built-in VDC Booster
PSE 30W/port; Total PoE power budget: 120W
Housing: IP40 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 95x70x29mm
|
NIS-3200-104PSG | 66P4SG41 | Industrial switch: 4 10/100/1000T PoE 30W + 1 SFP/1G, 24-56 VDC Booster |
 |
NIS-3200-105PSGB
| 4 ports PoE 30W | Voltage Booster 24 VDC
IEEE 802.3/802.3u/802.3ab/802.3x/802.3at/af (PoE auto detection)
8K MAC, 1Mbit buffer, Switch fabric 10Gbps
PoE pin assignment: 4/5(+), 7/8(-)
Redundant power input 24-56VDC; Built-in VDC Booster
PSE 30W/port; Total PoE power budget: 120W
Housing: IP40 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 95x70x29mm
|
NIS-3200-105PSGB | 66P4SG51 | Industrial switch: 4 10/100/1000T PoE 30W + 1 TP/1G, 24-56 VDC Booster |
 |
NIS-3200-105PSG
| 4 ports PoE 30W | no Fibre-Optic ports
IEEE 802.3/802.3u/802.3ab/802.3x/802.3at/af (PoE auto detection)
8K MAC, 1Mbit buffer, Switch fabric 10Gbps
PoE pin assignment: 1/2(+), 3/6(-). Mode A EndSpan PoE
Redundant power input 48-57VDC; Total PoE power budget: 120W
Relay alarm: Power off, PoE off, network broken
DIP switches: SFP mode selection | PoE auto-check function
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temp.: -40 ~ +75°C; Dimensions: 101x65x36mm
|
NIS-3200-105PSG | 63P4SG51 | Industrial switch: 4 10/100/1000T PoE 30W + 1 TP/1G, reboot PD |

 |
NIC-3200-101CG
| 1 10/100/1000Base-T | 1 SFP/1G
IEEE 802.3/ 802.3u/ 802.3ab/ 802.3x
1K MAC, 1Mbit buffer, Jumbo Frame: 16 K
Optical port 1x 100/1000M SFP with supporting LFP function
Redundant Power Input 12-56VDC
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temperature: -40 ~ +75°C; Dimensions: 59x36x50mm
|
NIC-3200-101CG | 61G1MFP1 | Industrial Gigabit Media Converter: 1 10/100/1000Base-T + 1 SFP/1G, mini size |
 |
NF-W02R
| 1 10/100Base-TX | 1 100Base-FX
IEEE 802.3/ 802.3u/ 802.3x
1K MAC, Maximum Packet Length:1552 bytes
Optical port: 1 x 100Base-FX | SC connector
Power Input 5-16VDC | Power adapter 12VDC / 0,5A
Housing: IP30 Protection, DIN Rail or Wall mounting
Operating Temperature: -10 ~ +55°C; Dimensions: 62x42x22mm
|
NF-W02R/A | 41FRWA02 | MC single fiber: 1310Tx/ 1550Rx, SM, SC, 20 km, 12VDC, mini size, DIN-rail clip |
NF-W02R/B | 41FRWB02 | MC single fiber: 1550Tx/ 1310Rx, SM, SC, 20 km, 12VDC, mini size, DIN-rail clip |
|